Normal MRA Brain Report Template (3D Time-of-Flight)
Normal brain MRA report template: 3D time-of-flight circle of Willis wording with vessel-by-vessel patency, plus flow-artifact and small-aneurysm notes.
Rather not fill in the blanks? Type a few findings and get this report written ↓
EXAMINATION: MR angiogram of the brain without intravenous contrast. CLINICAL HISTORY: [indication] COMPARISON: None available. TECHNIQUE: 3D time-of-flight MR angiography of the intracranial arteries with maximum-intensity-projection and multiplanar reformats, without intravenous contrast. FINDINGS: Internal carotid arteries: The cavernous and supraclinoid segments are patent bilaterally, with normal flow-related enhancement. No stenosis or aneurysm. Anterior circulation: The A1 and A2 segments of the anterior cerebral arteries and the M1 and M2 segments of the middle cerebral arteries are patent bilaterally. No occlusion, flow-limiting stenosis or aneurysm. Posterior circulation: The intracranial vertebral arteries, basilar artery and P1 and P2 segments of the posterior cerebral arteries are patent. No stenosis, occlusion or aneurysm. Circle of Willis: Patent, with conventional configuration. Anterior and posterior communicating arteries: [Visualized/not visualized]; nonvisualization is a common normal variant on time-of-flight imaging. IMPRESSION: 1. No intracranial aneurysm, flow-limiting stenosis or occlusion identified.
A sample dictation is ready below. Press generate, or type your own findings and end with “otherwise normal” to have the rest written out. No signup.
100 free reports over 14 days. No card, nothing to install.
Start your free trial →Please leave out patient identifiers. Text is de-identified before the AI sees it and is not stored. Demo output is not for clinical use.
Dictation notes
- Time-of-flight shows flow, not lumen — slow or in-plane flow mimics stenosis, so confirm any apparent narrowing on the source images before it reaches the impression.
- Sensitivity falls off below about 3 mm — when the indication is aneurysm screening, the impression should say small aneurysms below the resolution of the technique are not excluded.
- T1-hyperintense thrombus or methemoglobin can masquerade as flow on the MIPs — a “patent” vessel on the reformat still needs a look at the source and conventional sequences.
Related references
MyRadAgent’s radiology AI turns a scratch dictation into this report — structured, guideline-checked, in your own section headers and phrasing. It learns your style from every correction. Free trial: 100 reports over 14 days, no card, no IT ticket.
Draft a report with it → or try it here first — no signup ↑