MyRadAgent
Home › Tools › VDT calculator: pulmonary nodule volume doubling time

VDT calculator: pulmonary nodule volume doubling time

Enter the nodule diameter or measured volume on each study and the interval between scans, in days or as two scan dates. Volume scales with the cube of diameter, so modest diameter change means large volume change — the calculator makes that explicit, maps the result to the standard interpretation bands and writes the sentence for the report.

Need the whole report too? Type a few findings and get it written ↓

What one doubling looks like

First scandOne doubling later1.26 × dvolume × 2
Volume goes with the cube of the diameter, so a nodule that doubles in volume is only about 26% wider. Illustrative.

Volume doubling time: the step your answer falls on is highlighted.

Measured as
Diameter on first study (mm)
Diameter on follow-up (mm)
Interval given as
Interval between studies (days)
Formula. Volume scales with diameter cubed, so VDT = t · ln 2 / (3 · ln(d₂/d₁)). From two measured volumes it is VDT = t · ln 2 / ln(V₂/V₁). A 6 mm → 8 mm change is a 2.4× volume increase — diameter understates growth.
Draft the full report from this finding — free

A sample dictation is ready below. Press generate, or type your own findings and end with “otherwise normal” to have the rest written out. No signup.

Now try it on your own case.

100 free reports over 14 days. No card, nothing to install.

Start your free trial →

Please leave out patient identifiers. Text is de-identified before the AI sees it and is not stored. Demo output is not for clinical use.

Interpretation bands

Doubling timeTypical meaning
VDT under 400 daysA positive result in the NELSON screening protocol. For intermediate-sized nodules (about 5-10 mm, 100-300 mm³) NELSON found a 9.9% probability of lung cancer with a doubling time of 400 days or fewer. Infection or inflammation can also grow quickly; correlate clinically.
VDT 400-600 daysIndeterminate in NELSON: a 4.0% probability of lung cancer for intermediate-sized nodules.
VDT over 600 daysNegative in NELSON: a 0.8% probability of lung cancer for intermediate-sized nodules; very indolent malignancy is still possible. Note that subsolid adenocarcinoma-spectrum lesions can double over 3-5 years, so long-interval follow-up is still prudent for GGNs.

What a diameter change means in volume

Doubling time is the usual way to state a nodule's growth rate, and it is judged on volume. A nodule that looks only slightly larger has often grown a great deal: for a sphere, a 26% increase in diameter is one full doubling of volume.

DiameterDiameter changeVolume change
4 mm → 5 mm+25%+95%
6 mm → 7 mm+17%+59%
6 mm → 8 mm+33%+137%
8 mm → 10 mm+25%+95%
10 mm → 12 mm+20%+73%
15 mm → 17 mm+13%+46%
20 mm → 23 mm+15%+52%

What counts as growth

A doubling time is only worth calculating once the change is larger than measurement error. The published schemes set that bar differently.

SchemeGrowthHow doubling time is used
Lung-RADS v2022Mean diameter larger by more than 1.5 mm within a 12-month interval. Not used; the category follows size and growth.
NELSON trialVolume larger by 25% or more between two scans. Under 400 days is a positive result. At a later screening round 400-600 days is indeterminate and over 600 days negative.
British Thoracic Society 2015 (solid nodules)Volume change of 25% or more. Under 400 days: further diagnostic investigation. 400-600 days: surveillance or biopsy, by patient preference. Over 600 days: discharge or continued surveillance is considered.

Sources: American College of Radiology, Lung-RADS v2022; Zhao YR, et al. Cancer Imaging 2011;11(Spec No A):S79-S84; Callister MEJ, et al. Thorax 2015;70(Suppl 2):ii1-ii54.

Caveats

Related

Source. Standard exponential growth model; interpretation per the NELSON trial growth analyses (Horeweg N, et al. Lancet Oncol 2014;15(12):1332-1341). View on PubMed

Worked example

Case. A solid nodule measures 6 mm, and 8 mm on CT 180 days later.

  1. Diameter ratio: 8 / 6 = 1.333.
  2. Volume ratio: 1.333³ = 2.37, so the volume more than doubled.
  3. VDT = 180 × ln 2 / (3 × ln 1.333) = 124.8 / 0.863 ≈ 145 days.

Result. 145 days is under 400 days: a positive result in the NELSON screening protocol, for which further diagnostic investigation is usually considered.

On the same topic

Test yourself

Pure ground-glass nodule, 9 mm, confirmed persistent at the 6-month CT. Correct ongoing schedule:

Show the answer

A. Persistent ≥6 mm pure GGNs are followed every 2 years UNTIL 5 YEARS. Persistence does not end surveillance; growth or a new solid component ends the watching and starts the workup. PET is poor for pure ground glass.

Fleischner 2017 Pulmonary Nodule Quiz: 11 more questions →

Related calculators

Frequently asked questions

How is nodule volume doubling time calculated?

Volume doubling time comes from two diameters and the interval between scans, using the exponential growth model: VDT = t × ln 2 / (3 × ln(d2/d1)), where t is the interval in days. The factor of three enters because volume scales with the cube of diameter — a 26% increase in diameter is already a doubling of volume, which is why apparently modest diameter change can represent substantial growth.

What volume doubling time suggests lung cancer?

In the NELSON screening trial a doubling time under 400 days was a positive result, 400-600 days indeterminate and over 600 days negative. For intermediate-sized nodules (about 5-10 mm) the probability of lung cancer was 9.9%, 4.0% and 0.8% in those three groups. Infection and inflammation can also grow quickly, so a short doubling time is read with the clinical picture.

Does a long doubling time exclude malignancy in a ground-glass nodule?

No. Subsolid adenocarcinoma-spectrum lesions can have volume doubling times of three to five years, far beyond the 400-day benchmark derived from solid cancers, so long-interval follow-up remains prudent for ground-glass nodules even when calculated growth is slow. Conversely, the conventional benignity benchmark — two-year stability — applies to solid nodules; interval shrinkage favors an inflammatory or infectious cause.

Can volume doubling time be calculated from measured volumes?

Yes. With two volumes from volumetry software the formula is VDT = t × ln 2 / ln(V2/V1), with no factor of three, because the volumes are compared directly. A nodule of 120 mm³ that measures 300 mm³ after 180 days has a doubling time of about 136 days. For a spherical nodule the diameter and volume forms give the same answer.

How much growth in diameter equals one doubling of volume?

About 26%. Volume rises with the cube of the diameter, and the cube root of two is 1.26, so a nodule that goes from 8 mm to 10 mm has almost exactly doubled in volume. An increase from 6 mm to 8 mm is a 137% increase in volume, more than one doubling.

Is tumor doubling time the same as volume doubling time?

In imaging the two terms mean the same thing: the time a lesion takes to double in volume, assuming steady exponential growth. The arithmetic on this page applies to any roughly spherical lesion measured twice. The interpretation bands, however, come from studies of solid pulmonary nodules and should not be carried over to other organs.

References

  1. Horeweg N, van Rosmalen J, Heuvelmans MA, et al. Lung cancer probability in patients with CT-detected pulmonary nodules: a prespecified analysis of data from the NELSON trial of low-dose CT screening. Lancet Oncol 2014;15(12):1332-1341. doi:10.1016/S1470-2045(14)70389-4
  2. van Klaveren RJ, Oudkerk M, Prokop M, et al. Management of lung nodules detected by volume CT scanning. N Engl J Med 2009;361(23):2221-2229. doi:10.1056/NEJMoa0906085

Sources last checked November 2026.

This calculator, written into your report for you

MyRadAgent’s radiology AI drafts the full report and applies this guideline automatically, with the category and follow-up in the impression. Free trial runs in the browser: 100 reports over 14 days, no card, no IT ticket.

Try it on a report → or try it here first — no signup ↑
This is a reference implementation of a published guideline, for use by qualified clinicians. It does not account for patient-specific factors and is not a substitute for clinical judgment or a formal radiology consultation. See our full disclaimer.

BI-RADS, TI-RADS, LI-RADS, PI-RADS, O-RADS, Lung-RADS, CAD-RADS, NI-RADS and ACR are registered trademarks of the American College of Radiology. They are used here only to identify the published systems these tools implement; MyRadAgent is not affiliated with, sponsored by or endorsed by the ACR.